Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. Col. Bras. Cir ; 48: e20202587, 2021. graf
Article in English | LILACS | ID: biblio-1155357

ABSTRACT

ABSTRACT Objectives: the aim of this study was to compare the outcomes of a new silicone vascular prostheses with PTFE vascular prostheses, on a rabbit experimental model. Methods: forty rabbits underwent infra-renal aorta replacement with 4 mm diameter prostheses, twenty animals with PDMS and twenty animals with PTFE (control group). Retrograde aortic angiography was performed to assess patency. Histological graft samples were examined by electron microscopy to evaluate prostheses endothelialization. Results: patency rates were 100% for both grafts after 30 days; after 60 days, patency rate for PDMS was 92.3% (±7.4), and 73,8% (±13.1) at 90 days. PTFE grafts had patency rates of 87.5% (±11.7) at 60 and 90 days. No statistically significant difference was found in between groups for patency rates (p=0.62). Postoperative complications (death, paraplegia) rates (p=0.526) and aortic clamping times (p=0.299) were comparable in both groups. No statistically significant difference for stenosis was found on angiographical analysis between groups (p=0.650). Electron microscopy revealed limited anastomotic endothelial ingrowth in both prostheses. Conclusion: in this experimental model, PDMS and PTFE vascular prostheses had comparable outcomes and PDMS prosthesis could be used as a vascular graft.


RESUMO Objetivo: analisar novo tubo de silicone como material para prótese vascular e compará-lo a prótese de PTFE, em modelo experimental com coelhos. Métodos: quarenta coelhos foram submetidos a interposição, na aorta infrarrenal, de próteses de 4mm de diâmetro, sendo 20 animais com PDMS e 20 com PTFE (grupo controle). Foi realizada arteriografia retrógrada da aorta para avaliar a patência das próteses. Para avaliar a endotelização das próteses foi realizada microscopia eletrônica de maneira amostral pareada. Resultados: a patência em 30 dias foi de 100% para as duas próteses. Aos 60 dias, a taxa de patência do PDMS foi de 92,3% (± 7,4), e de 73,8% (±13,1) em 90 dias; as próteses de PTFE tiveram taxas de patência de 87,5% (± 11,7) aos 60 e 90 dias. Não foi observada diferença significativa entre as taxas de patência dos grupos (p=0,62). Não foi observada diferença entre os grupos quanto à evolução com complicações pós-operatórias (p=0,526) e quanto ao tempo de clampeamento da aorta (p=0,299). Não houve diferença significativa entre os grupos quanto ao grau de estenose das próteses (p=0,650) à avaliação angiográfica. A microscopia eletrônica mostrou crescimento endotelial limitado às regiões próximas às anastomoses nos dois tipos de próteses. Conclusões: o PDMS mostrou-se passível de utilização como prótese vascular, com resultados comparáveis aos do PTFE no modelo utilizado.


Subject(s)
Animals , Aorta/surgery , Polytetrafluoroethylene/therapeutic use , Silicones/therapeutic use , Blood Vessel Prosthesis , Polyesters , Rabbits
2.
Military Medical Sciences ; (12): 876-880, 2015.
Article in Chinese | WPRIM | ID: wpr-484674

ABSTRACT

The traditional approach to accessing healthcare information restricts the further development of healthcare services,thus unable to meet the growing needs of individual healthcare.The flexible sensor technology has emerged along with the development of new materials,machinery and manufacturing technology.As a result,textiles,accessories,human skin and even internal body organs can be integrated with various sensors.The popularization of flexible sensors provides new methods for monitoring health,improving therapeutics,investigating disease status and building the human-machine in-terface.Through a systematic investigation of literature,this paper reviews the applications of flexible sensors in health-care,discusses the key technologies,and introduces the common materials and manufacturing technology.

3.
São Paulo; s.n; 2014. [72] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: lil-750126

ABSTRACT

Introdução: Apesar de bons resultados descritos na literatura, o substituto ideal para a utilização como remendo no fechamento arterial ainda não existe. Por este motivo, ainda há espaço para a busca por remendo que seja biocompatível, e que apresente facilidade de manuseio e resultados satisfatórios. Avaliamos remendos arteriais de silicone (polidimetilsiloxano com reforço em poliéster - PDMSr) em comparação com remendos arteriais de PTFEe. Objetivo: O objetivo deste trabalho é comparar, em modelo experimental, em coelhos, os resultados de remendos arteriais feitos em PDMSr com remendos de PTFEe. Materiais e Método: A amostra foi definida em 10 animais que completassem todas as etapas da pesquisa em cada grupo. Os animais foram submetidos à laparotomia mediana e abertura longitudinal da aorta de aproximadamente 8mm, realizando-se o seu fechamento com remendo do grupo selecionado, seguido do fechamento por planos. Os animais foram mantidos em biotério até o 60º PO, quando, então, realizou-se arteriografia de controle, e análise macro e microscópica de peça. Resultados: Para se atingir a amostra desejada, foram necessários 12 procedimentos no grupo PDMSr e 16 no grupo PTFEe. Ocorreram 2 óbitos no grupo PDMSr e 6 no grupo PTFEe. Apesar do número maior de óbitos no grupo PTFEe não houve diferença estatística na sobrevida entre os grupos. Um animal do grupo PDMSr apresentou monoparesia em pata posterior direita e um animal do grupo PTFEe apresentou hérnia incisional. Não houve diferença estatística nas complicações entre os grupos. O tempo operatório foi estatisticamente maior no grupo PTFEe quando comparamos todos os animais, fato que não se repetiu quando excluímos os animais que faleceram...


Introduction: Although good results are reported for various materials for use as patches for arterial closure, as yet none of these is ideal. Therefore, research is continuing into development of a patch that is biocompatible and provides ease of handling, while having satisfactory outcomes. A new silicone arterial patch (polydimethylsiloxane reinforced with polyester fabric, PDMSr) was compared with patches made of expanded polytetrafluoroethylene (ePTFE). Objective: To compare the outcomes between arterial patches made of PDMSr with those made of ePTFE, in an experimental rabbit model. Materials and Method: Rabbits were placed in two groups, and received either PDMSr or ePTFE arterial patches (PDMSr group and ePTFE group, respectively). The animals underwent laparotomy and longitudinal opening of the aorta, which was then closed with the selected patch, followed by suture of all layers. The animals were kept in their cages until the 60th postoperative day, when arteriography, removal of the aorta, and macroscopic and optic and scanning electron microscopic analyzes of the aorta were performed. Ten rabbits from each group that had completed all stages of the research were included in analyses. Results: Twelve procedures were performed in the PDMSr group and 16 in the ePTFE group. There were 2 deaths in the PDMSr group and 6 in the ePTFE group. Despite the higher number of deaths in the ePTFE group, there was no statistical difference in survival rate between the groups. One animal in the PDMSr group developed monoparesis in its right hind paw and 1 animal in the ePTFE group had an incisional hernia. There was no statistical difference in complications between the groups. The operative time was significantly longer in the ePTFE group when all animals were included in analysis, but not when animals that died were excluded...


Subject(s)
Animals , Female , Rabbits , Aorta, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation , Dimethylpolysiloxanes , Endothelium, Vascular , Polyesters , Polytetrafluoroethylene , Silicones , Vascular Grafting , Vascular Patency , Implants, Experimental , Rabbits
4.
Korean Journal of Urology ; : 182-189, 2014.
Article in English | WPRIM | ID: wpr-65241

ABSTRACT

PURPOSE: We investigated the efficacy of transurethral injection of Macroplastique bulking agent (Uroplasty) for male stress urinary incontinence (SUI) after prostate surgery. MATERIALS AND METHODS: This retrospective review included men with SUI treated by transurethral injection for symptoms resulting from prostate surgery. Patients were evaluated at 1 month and 6 months after injection by determining the number of pads used per day and changes in incontinence symptoms. Treatment success was defined as use of 1 pad or fewer per day combined with subjective symptom improvement. RESULTS: The study population comprised 30 men with a mean age of 66.1+/-5.3 years. Of the 30 patients, 24 (80.0%) underwent prostate cancer surgery and the remaining 6 (20.0%) underwent surgery for benign prostatic hyperplasia. The preinjection pad number was 2.9+/-1.9 pads per day. After injection treatment, the mean follow-up period was 9.3+/-12.7 months and the success rate was 43% (13/30) at 1 month and 32% (6/19) at 6 months. Injection was more likely to result in a successful outcome in patients with no preinjection radiation treatment history and higher abdominal leak point pressure (ALPP) than in those with a previous history of radiation treatment and lower ALPP, although this result was not statistically significant. Acute urinary retention occurred in 5 patients (17%). CONCLUSIONS: Transurethral Macroplastique injection treatment is a relatively non-invasive treatment method for male SUI with a success rate of 43% at 1 month and 32% at 6 months. Patients with a higher ALPP and no previous history of radiation therapy may experience better treatment outcomes.


Subject(s)
Humans , Male , Dimethylpolysiloxanes , Follow-Up Studies , Methods , Prostate , Prostatic Hyperplasia , Prostatic Neoplasms , Retrospective Studies , Urethra , Urinary Incontinence , Urinary Retention
5.
Chinese Journal of Laboratory Medicine ; (12): 920-923, 2009.
Article in Chinese | WPRIM | ID: wpr-380596

ABSTRACT

in vitro fertilization in future.

SELECTION OF CITATIONS
SEARCH DETAIL